1 SciSolLogoWhite

(844) 404-4588

24/7 Customer Support

15KW Mid-Frequency Split Induction Heater w/ Timers 30-80KHz

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare

$3,990.00$4,035.00

SKU: IH15AB Category: Brand:

Note: This model only available in 208-240 volt single phase.

Across International IH series mid-frequency induction heaters are designed to operate between 30 and 80 kHz. Mid-frequency heaters are excellent for small parts heating, cutting, diamond tool brazing, soldering copper plumbing fittings, auto parts heat-treating, annealing of stainless steel containers and more.

Mid-frequency induction heaters are the simplest in terms of design and implementation. With their low cost of ownership and maintenance, they are the most popular and reliable machines. The 15kW models are especially popular for their large power capacity and small footprint at an affordable price. This makes them standard equipment for many factories, labs and workshops where 230V AC is available.

 

Safety Features

  • Overvoltage protection: machine shuts down when input voltage is over 245V. Overvoltage light will turn on and buzzer will sound continuously. Alarm and light shut off automatically when voltage goes below 245V.
  • Overheat protection: if sensor detects heat radiatortemperature is over 55C, machine will shut down, overheat light will turn on and buzzer will sound continuously. Increase water pressure or lower water temperature until alarm goes off itself.
  • Overcurrent/malfunction protections: machine will shut down, indicator light turned on and buzzer sounds continuously if one of these situations occurs:
    • One of the machine parts becomes overheated
    • Interfering signal detected
    • Short circuit between work pieces and induction coils
    • Machine malfunctions
    • Induction coils touching each other
    • Input voltage is too low
  • Low water pressure protection: if water pressure goes below 29 PSI, machine will shut down, water protection light will turn on and buzzer will sound continuously.

IMPORTANT!!

  • Always wear protective gear and goggles when operating the machine. Crucibles must be covered all the time during operation. Across International is not responsible for any injury or damage caused by misuse.
  • Do not run no-load operation for a long period of time, it might cause damage to the machine.
  • Circulating water must be pure, clean and below 45C.
  • Machine must be grounded properly all the time during operation.
  • Do NOT use single-turn coil if coil diameter is smaller than 4 inches, it will cause high frequency damage to the machine.
  • Thread tape (or related material) is absolutely prohibited during installation of induction coils.

 

 