HyperLogic’s Commercial Reverse Osmosis line includes system configurations that produce 2,000 to 19,000 gallons of pure water, per day. Each system is custom built based on water chemistry and site specific needs, ensuring successful water management solutions for maximum productivity and efficiency. Our custom systems feature the lowest wastewater to product water ratios in the hydroponic industry, with up to an ultra-efficient 80% recovery rate. HydroLogic Commercial Reverse Osmosis water purification systems are leak and performance tested and will arrive in perfect working order having already passed our stringent quality assurance guidelines. With hundreds of successful grow operation installations across the USA and Canada, HyperLogic is the #1 best selling Reverse Osmosis brand in the hydroponic industry.
Turnkey Custom Systems with Plug & Play Convenience
The Plug & Play Skid Assembly is a turnkey system that comes equipped with all the water treatment equipment mounted on an all metal, powder coated skid with a fiberglass reinforced plastic grating floor. The pre-treatment equipment, the reverse osmosis (RO) unit, and options such as re-pressurization pumps for distribution of RO water come fully assembled, plumbed together, wired, and pre-programmed specifically to your site’s unique water quality conditions. Just forklift the skid into place, connect the inlet, drain and product water lines, and hard wire in the single electrical connection to be up and running quickly. The startup procedure is greatly simplified. No need to hire plumbers for long hours of installation and programming, the time spent on the actual install is virtually eliminated with this plug and play option. You are ready to produce the highest quality water with the confidence that everything is professionally plumbed and automated. Highly recommended for systems with multiple components. Leave the hard work to us and have pure water flowing shortly after receiving your customized HyperLogic skid system.
- Liquid filled pressure gauges for pre-filter in & out, concentrate pressure and system pressure
- Stainless steel multistage high pressure RO pump with SS pump throttling valve
- 5 micron 20″ x 4.5″ cartridge filter & housing sediment pre-filter
- Product, concentrate & recycle flowmeters
- System control, recycle control & pump throttle valves
- Stainless steel membrane pressure vessels
- Low pressure pump protection switch
- Powder coated, heavy gauge carbon steel frame
Features
- Powder coated all-metal skid and back panel
- Fiberglass reinforced, no-rust floor
- Single point inlet, outlet, and drain
- All components and plumbing go through rigorous quality control with leak and performance testing
- All components are pre-programmed specific to your application
- Schedule 80 plumbing is used throughout the system
- Pressure gauges and sample ports are installed after each stage of filtration for simple troubleshooting and monitoring the performance of each filtration stage
- All electrical leads tied together to a single connection point
Available in three standard sizes (Long x Deep x Tall)
- 72″ x 30″ x ~96″
- 96″ x 40″ x ~96″
- 120″ x 60″ x ~96″
Also available in custom sizes
Controller
Monitors and Controls:
|
Controller Features:
|
LED Display:
|
Reverse Osmosis System Power Options
- 208/220-240V, 1Ph, 60Hz (2,000-10,000 GPD)
- 208/220-240V, 1Ph, 60Hz (10,800-19,000 GPD)
- 208/220-240V, 3Ph, 60Hz (5,800-19,000 GPD)
- 460-480V, 3Ph, 60Hz (5,800-19,000 GPD)
Skid System Power Options
Commercial Reverse Osmosis System Specifications
The Maximum Recovery can potentially be increased to operate more efficiently depending on certain water quality parameters set forth by HyperLogic and can be discussed on a case-by-case basis.
Operating Parameters and Limits
RO Operating Parameter | Limit |
Feed TDS | <1,000 PPM |
Feed Water Turbidity | Less than 1 NTU |
Feed water silt density index (SDI) | 3 maximum |
Minimum Dynamic Feed Pressure | >45 psi |
Maximum Static Feed Pressure | <80 psi |
Maximum Feed Iron | 0.05 ppm |
Feed Water Silt Density Index | 3 maximum |
Feed Water Chlorine Level | 0 ppm |
Feed Water Hardness | 0 ppm |
Feed Water Temperature Range | 40-100°F |
Capacity Basis | 24 Hours/Day |
Dimensions
- Commercial Systems rated at 77°F (25°C) using 1,000 ppm sodium chloride solution operating at approximately 200 psi pressure. System capacity changes significantly with water temperature and feed TDS. For higher TDS, a water analysis must be supplied and could result in modifications to the system
- NOTE: Additional Pre-treatment may be necessary based on feed water chemistry
- For higher TDS, problematic contaminants, or by request; we can project the permeate & concentrate water quality, flow rates, and pressures using our fully integrated modeling software to improve system design for maximum efficiency.
Options:
Non-Skid System
(Plumb It Yourself Option)
Sediment Bag Filter
Post-filtration
Pump Skid
Ultraviolet Sterilization & Storage Tank Recirculating UV System
Post-Injection
Blending Valve System
Membrane Clean-In-Place System (CIP)
Specification: HyperLogic Commercial Reverse Osmosis
|